Campus profile Under construction

Frontier

Vantage Data Centers · Shackelford County, Texas

The resource footprint

Modelled average

In one day, this campus would consume about

10.950-metre swimming pools

Filled with the volume of water consumed by the campus and its electricity supply.

The actual estimate7,176,570 US gallons consumed

50-metre pools · 2 metres deep
Each diagram = 1 pool. Partial shading shows the remainder.
At the campus700,153 galMaking its electricity6,476,417 gal

Power-plant water may come from a different watershed. This is a volume comparison, not a claim that households lose this water.

If announced plans are fully built · Not operating yet · Annual model spread evenly over time, not a live meter. Site estimates may differ by roughly ±40%.

Comparison sizes & sources

One pool = 50 × 25 × 2 metres = 2.5 million litres (about 660,430 US gallons). Pool depths vary; this is a defined comparison size.

One home-year = 10,791 kWh, the EIA’s 2022 average US residential electricity purchases. This excludes electricity generated at home and is a fixed US benchmark for all sites.

One car-year = 4.6 tonnes CO₂, the EPA’s typical passenger vehicle tailpipe estimate. The campus model is in CO₂e; the comparison expresses approximate climate scale, not equal mixtures of pollutants.

Monthly values are annual totals ÷ 12; daily values are annual totals ÷ 365. Actual demand varies. Comparisons cover the whole campus, including non-AI uses.

Water: see the numbers and sources

This is water used up, mainly through evaporation. Power-generation water may be used in a different watershed.

Total water use2,619M gal/yr
Evaporated on site256M gal
Making the power2,364M gal
Household comparison32,743homes, at 80,000 gal/year
Pressure on local water
High — a regional measure of demand compared with available water
Where the water comes from
Municipal potable supply
Cooling
Closed-loop liquid
Basis
Modelled from cooling design — WUE 0.08 L/kWh
Air: see the numbers and sources

The totals include nitrogen oxides, sulphur dioxide and fine particles. They cover both this site and the power plants supplying it.

Nitrogen oxides2,443t/yr
Sulphur dioxide1,555t/yr
Fine particulates285t PM2.5
Health (EPA)$238M/yr
Health range
$82.4–238 million a year. Lower bound is EASIUR national mid-range; upper is EPA benefit-per-ton at a ~$12M VSL.
Statistical deaths
19.9 a year at that VSL — a national-average conversion from tons, not a local concentration study.
Equals
3,053,307 cars of NOx
Where it burns
ERCOT — Texas + 20% turbines on the site itself
Generation mix
Gas 40 · Wind 24 · Solar 11 · Coal 13 · Nuclear 9
Emitted at the fence line
27% of this site's criteria pollution
Diesel backup
Research found 670+ gas reciprocating engines (2.58 GW) proposed as on-site generation — prime power, not backup diesel.
CO₂e
4,530 kt/yr — climate, not air quality
The project, approvals and community concerns
Who asked for it
Undisclosed hyperscale customers; Vantage has said the campus is substantially pre-leased
Who approved it
Shackelford County abatements; ERCOT interconnection; Texas SB6 (2025) large-load curtailment obligations apply
What it serves
Hyperscale AI tenants — leases signed, tenant names withheld
IT capacity
0 MW current capacity / 1,400 MW full-build scenario

A $25B, 1.4 GW campus on ranch land an hour from Abilene. Texas SB6 now lets ERCOT order loads this size to curtail during emergencies — the first US law treating data centers as dispatchable demand.

water-stressed basinon-site gas turbines

Keep this guide handy

32.7500°, -99.3500°

Quote or share these estimates

Gigawatt Ledger (2026). Frontier: water and air. https://gigawatt-ledger.pages.dev/site/shackelford/. Modelled from disclosed capacity; site-level error ±40%.